INDUSTRIAL WATER TREATMENT ›› 2015, Vol. 35 ›› Issue (2): 50-53. doi: 10.11894/1005-829x.2014.35(2).050

Previous Articles     Next Articles

Pilot-scale study on PAC-UF process for the treatment of micro-polluted raw water under different aeration conditions

Ge Huafei1, Cai Lei2, Deng Huiping1, Shi Jun1   

  1. 1. School of Environmental Science and Engineering, Tongji University, Shanghai 200092, China;
    2. West Branch, China Academy of Urban Planning & Design, Chongqing 400021, China
  • Received:2014-10-27 Online:2015-02-20 Published:2015-03-18

不同曝气方式下PAC-UF工艺处理微污染原水的中试研究

葛华飞1, 蔡磊2, 邓慧萍1, 史俊1   

  1. 1. 同济大学环境科学与工程学院, 上海 200092;
    2. 中国城市规划设计研究院西部分院, 重庆 400021
  • 作者简介:葛华飞(1989—),同济大学硕士研究生。电话:13816144272,E-mail:1233356@tongji.edu.cn。
  • 基金资助:

    国家水体污染控制与治理科技重大专项(2014ZX07405002)

Abstract:

A pilot simulated test on the demonstration project of biological powdered activated carbon-ultrafiltation(PAF-UF) in a Zhejiang water plant has been accomplished. The change rules of pollutant removing efficiency and membrane pressure difference under two kinds of aeration conditions:continuous aeration and aeration only while backwashing, have been investigated. It is found from the research that after the process has run steadily, under the two kinds of aeration conditions, the differences of the removing rates of ammonia nitrogen and CODMn are not big, but under the condition without continuous aeration, the removing rates of UV254 and soluble organic matter are decreased, and membrane pressure difference grows faster.

Key words: micro-polluted raw water, powdered activated carbon, ultrafiltration

摘要:

对浙江某水厂生物粉末活性炭-超滤(PAC-UF)示范工程进行中试模拟试验, 考察了在连续曝气和仅反冲洗时曝气2种不同曝气方式下污染物的去除效果和膜压差的变化规律。研究发现, 工艺运行稳定后, 2种曝气方式下氨氮、CODMn的去除率差距不大, 而取消连续曝气条件下UV254和溶解性有机物的去除率降低, 膜压差增长较快。

关键词: 微污染原水, 粉末活性炭, 超滤

CLC Number: