Abstract:
By means of the combined technology of lowering hardness,neutralization and desalination,etc.,the discharged wastewater of circulating cooling water system can be treated. The purified water quality(total hardness and calcium ion components)is greatly better than fresh water,and can completely be reused as make-up water for circulating cooling water system. The experimental results show that ratio of wastewater reuse reaches more than 86%,and decrease cost of production, and saves a great quantity of industrial water.
Key words:
wastewater reuse,
circulating cooling water,
lowering of hardness and desalination
摘要:
采用降硬、中和、脱盐等联合工艺技术对循环冷却水系统的排污水进行处理,处理后的净水水质(总硬以及Ca2+含量)大大优于新鲜水,完全可作为补充水回用于循环水系统。试验结果表明,采用该工艺可使循环冷却水系统的污水回用率达到86%以上,降低了生产成本,节约了大量的工业用水。
关键词:
污水回用,
循环冷却水,
降硬脱盐
CLC Number:
Wu Yunjuan, Zhang Lihui, Zhang Yanhe, Liu Zhenfa, Xia Zhihua. Experimental research on wastewater reuse technology of circulating cooling water system[J]. INDUSTRIAL WATER TREATMENT, 2008, 28(1): 60-62.