Abstract:
The combined process, physicochemical pretreatment-UASB-hydrolysis acidifying-contact oxidation-bio-logical activated carbon filter, has been used for treating chemical wastewater in a company.The operation results show that the pretreatment process can obviously reduce the concentrations of chemical oxygen demand (COD) and salinity in high-concentration wastewater.The water quality of the effluent treated by the whole process reaches the take-over requirements.
Key words:
chemical wastewater,
iron-carbon microelectrolysis,
contact oxidation,
biological activated carbon filter
摘要:
某公司采用物化预处理-UASB-水解酸化-生物接触氧化-活性炭生物滤池工艺处理化工废水,运行结果表明,预处理工艺可明显降低高浓度废水的COD和盐分,整个工艺处理出水水质达到接管要求。
关键词:
化工废水,
铁炭微电解,
接触氧化,
活性炭生物滤池
CLC Number:
Ji Zhen, Wang Xubo, Lü Wenming, Zhu Jianmei. Treatment of chemical wastewater by the physicochemical pretreatment-anaerobic-aerobic process[J]. INDUSTRIAL WATER TREATMENT, 2017, 37(1): 92-94.