INDUSTRIAL WATER TREATMENT ›› 2007, Vol. 27 ›› Issue (6): 54-57. doi: 10.11894/1005-829x.2007.27(6).54

Previous Articles     Next Articles

Research of treating crythromycin wastewater in an anaerobic fluidized bed reactor

Zhou Jian, Zhang Huizhan, Fang Chunyu   

  1. Department of Biological Engineering, Sichuan University of Science and Engineering, Zigong 643000, China
  • Received:2007-03-10 Revised:2007-03-10 Online:2007-06-20 Published:2010-10-01

厌氧流化床处理红霉素废水的研究

周健, 张会展, 方春玉   

  1. 四川理工学院生物工程系, 四川 自贡 643000
  • 作者简介:周健(1963- ) , 1996 年毕业于四川大学, 硕士, 教授。电话: 13990022528, E-mail: zhoullxx2000@yahoo.com.cn

Abstract:

Crythromycin wastewater is treated in an anaerobic fluidized bed reactor (AFB) with granular activated carbon as carrier, operating at 33- 35 ℃. The operating characteristic is studied. The test result demonstrates that the removal efficiency of COD and BOD are 76.6% and 65.9% respectively as influent COD is 6 900 mg/L and HRT is 4.4 h. The non-biodegradation organism concentration is obtained by Garrett - Sawyer formula. And the degradation equation for the anaerobic digestion of crythromycin wastewater is concluded by employing the Monod model.

Key words: crythromycin wastewater, wastewater treatment, anaerobic fluidized bed

摘要:

研究了中温(33~35℃)条件下,厌氧流化床(AFB)反应器处理红霉素废水的运行特性。结果发现:进水COD为6 900 mg/L、HRT为4.4 h时,COD、BOD的去除率分别达到了76.6%、65.9%。最后利用Garrett-Sawyer关系式求出了难生物降解的有机物浓度,并利用Monod模型对实验结果进行了动力学分析,得出了红霉素废水中温条件下厌氧消化过程的基质降解规律。

关键词: 红霉素废水, 废水处理, 厌氧流化床

CLC Number: