INDUSTRIAL WATER TREATMENT ›› 2006, Vol. 26 ›› Issue (7): 19-22. doi: 10.11894/1005-829x.2006.26(7).19

Previous Articles     Next Articles

Study on function performance of nitrous nitrification and anammox process

Ye Jianfeng1, He Xiaochu2, Chen Feng3   

  1. 1. School of Environmental Science and Engineering, Tongji University, Shanghai 200092, China;
    2. Shanghai Academy of Environmental Sciences, Shanghai 200233, China;
    3. Municipal Drainage Administration Minhang, Shanghai 200237, China
  • Received:2006-02-22 Online:2006-07-20 Published:2010-10-01

亚硝酸型硝化-厌氧氨氧化工艺运行性能的研究

叶建锋1, 何校初2, 陈峰3   

  1. 1. 同济大学环境科学与工程学院, 上海 200092;
    2. 上海市环境科学研究院, 上海 200233;
    3. 上海市闵行区排水管理所, 上海 200237
  • 作者简介:叶建锋(1976- ),同济大学环境科学与工程学院在读博士生。E-mail:0410050029@smail.tongji.edu.cn。
  • 基金资助:

    江苏省自然科学基金项目(BS2002038)

Abstract:

Based on the successful starting up of the two bioreactors, the removal efficiency of anammox bioreactor couldn′t synchronizally increase when the average volumetric ammonia loading rate is oversized. A new treatment system has been set up by nitrous nitrification bioreactor and anaerobic ammonia oxidation bioreactor. The parameters of the bioreactor system are as follows: average ammonia removal rate is more than 95%, volumetric total ammonia removal rate is 20.1mg/ (L·d), total organic compound removal rate is about 90%.

Key words: denitrification, nitrous nitrification, anaerobic ammonia oxidation, bioreactor

摘要:

研究评估了生物亚硝酸型硝化反应器与Anammox反应器组成的新型脱氮系统的可行性及该系统的脱氮效率。在两个反应器成功启动的基础上,得出反应器容积负荷率过大时,厌氧氨氧化反应器的去除能力未能同步的得到提高;脱氮系统总的NH4+-N平均去除率达95%以上,系统的容积氨氮去除率为20.1mg/(L.d),有机物的总去除率稳定在90%左右。

关键词: 脱氮, 亚硝酸型硝化, 厌氧氨氧化, 生物反应器

CLC Number: