INDUSTRIAL WATER TREATMENT ›› 2003, Vol. 23 ›› Issue (4): 70-72. doi: 10.11894/1005-829x.2003.23(4).70

Previous Articles     Next Articles

Determination of optimum operation parameters for DCCH type clarifer

Tian Maodong, Zhang Qingtao, Liu Quan   

  1. Huaneng Power International Inc. Dezhou Power Plant, Dezhou 253024, China
  • Received:2002-11-04 Online:2003-04-20 Published:2010-10-01

DCCH型澄清池最佳运行参数的确定

田茂东, 张清涛, 刘泉   

  1. 华能德州发电厂, 山东 德州 253024
  • 作者简介:田茂东(1966- ), 1997 年毕业于大连理工大学研究生院, 获工学硕士学位, 工程师。电话:0534-2432735。

Abstract:

After more than one year' s test running,the optimum operation parametersof DCCH type clarifer have been determined.The main factors are the dosage of PAC, the rotation speed of stirring machine, temperature and emission amount of sludge.

Key words: dosage of PAC, rotation speed, temperature, emission amount of sludge

摘要:

经过一年多时间的探索,确定了DCCH型澄清池的最佳运行条件,影响该类型澄清池运行的主要参数是混凝剂用量、搅拌机转速、温度和排泥量等。

关键词: 混凝剂用量, 搅拌转速, 温度, 排泥量

CLC Number: