INDUSTRIAL WATER TREATMENT ›› 2002, Vol. 22 ›› Issue (3): 51-52. doi: 10.11894/1005-829x.2002.22(3).51

Previous Articles     Next Articles

Catalytic spectrophotometric determination of trace fluoride in wastewater in power plants

XIA Changbin   

  1. Dept. of Chemical Engineering, Xiangtan Polytechnic University, Xiangtan 411201, China
  • Received:2001-11-09 Online:2002-03-20 Published:2010-10-01

催化光度法测定电厂废水中的微量氟化物

夏畅斌   

  1. 湘潭工学院化学工程系 湖南湘潭 411201
  • 作者简介:夏畅斌(1960- ),1989年毕业于中国矿业大学北京研究生部,现为北京科技大学土木与环境工程学院博士研究生,教授。
  • 基金资助:

    湖南省科技攻关项目(010-962-54)子课题

Abstract:

When the pH value of glycine-HCl buffer solution is 2.76,Fe3+ catalyzes strongly the fading reaction of 2,4-diamonophenol(DAP) by oxidizing with H2O2.Free F- ions and Fe3+ form stable complexes [FeF6]3-,thus reducing its catalytic effect and its reducing extent is liner with the concentration of F-.Based on this study,a rapid and simple catalytic spectrophotometric method for the determination of F- ions has been developed.The results show that the range of determination is0.0~9.0mg/L for F-,the detection limit is0.09 mg/L for F-,and RSD(n=6)5%.The method has been applied to the determination of trace fluoride in power plants wastewater and running waters with satisfactory results.

Key words: catalytic spectrophotometry, fluoride, wastewater

摘要:

研究了在pH2.76氨基乙酸-盐酸缓冲溶液中,Fe3+对H2O2氧化2,4-二氨基苯酚(DAP)褪色具有催化作用,游离F-离子与Fe3+形成的稳定络合物 [FeF6]3-可阻抑催化作用,阻抑程度与F-量线性相关。基于此,建立了测定微量F-的催化光度分析的新方法。结果表明,有色溶液的最大吸收波长为500nm,测定的线性范围为0.0~9.0mg/L,检出限为0.09mg/L,RSD(n=6)5%。灵敏度高、选择性好、分析速度快,应用于电厂废水和自来水中微量F-的测定,结果满意。

关键词: 催化光度法, 氟化物, 废水

CLC Number: