表2 纳滤膜及其处理含铀溶液的性能
Table 2 Nanofiltration membranes and their performance in treatment of uranium-containing solution
纳滤膜型号制造商操作条件(原料液铀质量浓度,操作压力)铀截留率/%

通量/

(L·m-2·h-1·MPa-1)

参考

文献

TFC-SKoch Membrane System0.295 mg/L,1.1 MPa97.6~23〔4〕
NF-1Sepro15 mg/L,1.0 MPa40.8~84.4~45〔21〕
NF-2Sepro15 mg/L,1.0 MPa37.3~96.6~212〔21〕
G10Osmonics2 mg/L,0.1 MPa40—〔23〕
NF270Dow Filmtec40 mg/L,1.0 MPa976〔24〕
DLOsmonics2 mg/L,0.1 MPa95—〔23〕
1 mg/L,0.8 MPa94~9835~70〔26〕
DKOsmonics2 mg/L,0.1 MPa99—〔23〕
1 mg/L,0.8 MPa96~9935~70〔26〕
HLOsmonics1 mg/L,0.8 MPa8835~70〔26〕
NF45Dow Filmtec1 mg/L,0.8 MPa8135~70〔26〕
NF90Dow Filmtec0.295 mg/L,1.1 MPa>99.7~21〔4〕
40 mg/L,1.0 MPa>9510.6〔24〕
1 mg/L,0.8 MPa8235~70〔26〕
8 mg/L,0.5 MPa9767.4〔27〕
陶瓷膜—2 mg/L,1.0 MPa9114.1〔28〕